Features a manual plug-in connection. The heat cable is switched manually. This method requires supervision to work effectively.
Dual user attachable configuration for OEM connection of cable. Units are dual voltage rated. Operation and trip times equal or exceed that of the GFCI’s.
Volts/Amps
120V/20A and 240V/20A
Accepts
12 - 18 AWG. (SJT)
Trip Level
30 mA
Voltage Surge Withstand
3kv ringwave test and 4kv/2kA surge immunity test
Frequency
50 / 60 Hz
Endurance
5000 operations minimum
Overload Current
Six times rated current
Operating Temperature Range
10°C to 60°C
Insulation Voltage
1500 VRMS - 1 Min.
Power On Indication
Lighted indicator
10 Foot Pig-Tail Power Cord w/Molded Plug
Product code: EPT-10
20 AMP 30mA GFCI Plug Kit
120VAC code: EGFI-120
240VAC code: EGFI-240